What should I do if the booster pump buzzes and doesn't fill water

Feb 28,2025

The problem of the booster pump buzzing but not filling water may involve multiple aspects. The following are some possible reasons and corresponding solutions: 1. Possible reasons

1. Pressure control system failure: Under normal circumstances, the booster pump should stop working after reaching the preset pressure. If the pressure control system malfunctions, the booster pump may continue to operate but cannot effectively boost the pressure.

2. Abnormal function of check valve: The main function of check valve is to prevent water flow from reversing. If the quality of the check valve is poor or fails, the pressurized water may flow back to the inlet end of the pump, causing a pressure drop and triggering the pump to restart, accompanied by a buzzing sound.

3. Leakage of pump outlet pipe: - Leakage of the outlet pipe will reduce the water pressure in the pump chamber, causing the pump to restart continuously and make a buzzing sound.

4. Sensor malfunction: - If the pressure sensor malfunctions and cannot provide accurate feedback on pressure information, the booster pump may continue to operate but cannot achieve effective boosting.

5. Frequent water usage: For booster pumps that use differential pressure control, if the water usage frequency is too high, it may cause the pump to start and stop frequently, and produce a buzzing sound.

6. Low water level or no water in the pump: - If the tap water level is lower than the impeller plane of the booster pump or there is no water in the pump, the booster pump will not be able to pump water.

7. Blockage of inlet and outlet pipe diameters: - Blockage of inlet and outlet pipes can affect the flow of water, causing the booster pump to malfunction.

8. Mechanical failure or installation issues: Wear and looseness of internal mechanical components of the booster pump, or unstable and unbalanced installation, may cause buzzing sound during operation and affect the water filling effect. 2、 Solution method

1. Check and repair the pressure control system: - Check if the pressure control system is working properly, and promptly repair any malfunctions.

2. Replace check valve: - If the check valve functions abnormally, a reliable quality check valve should be replaced.

3. Inspect and repair the pump outlet pipe: - Carefully check if there is any leakage in the pump outlet pipe, and repair it in a timely manner.

4. Check and replace the sensor: - If a sensor malfunction is suspected, check the working status of the sensor and replace the faulty component.

5. Adjust water usage habits or replace controllers: For frequent water usage, consider adjusting water usage habits or replacing with a frequency converter controlled booster pump to reduce the number of starts and stops.

6. Ensure sufficient water level: - Ensure that the tap water level is above the level of the booster pump impeller and that the pump is filled with water.

7. Clean the inlet and outlet pipelines: - Turn off the power supply of the booster pump, clean the blockages in the inlet and outlet pipelines, and ensure smooth water flow.

8. Check and repair mechanical faults: - If there is suspicion of buzzing and water failure caused by mechanical faults or installation issues, professional personnel should be hired for inspection and repair. 3、 Summary

The problem of the booster pump buzzing but not being filled with water may be caused by various reasons, and it needs to be investigated and resolved according to the specific situation. During the inspection and maintenance process, it is essential to pay attention to safety and follow relevant operating procedures. If the problem is complex or difficult to solve, it is recommended to contact professionals for handling.